ALA-S80-280_DataSheet.pdf
Size: 126 KB
Type: pdf
-
ALA-S80-280_3D_Model.stp
Size: 2 MB
Type: stp
ALA-S80-280
- NOMINAL FORCE: 1000 N
- LENGTH COURSE: 280 mm
- LINEAR SPEED: 70 mm/s
PRODUCT INFORMATION
1000 N nominal and 1500 N maximum thrust.
Under 1500 N load, it can stand without slipping.
Behind the ALA-S80-280 is a modular drive unit
with RS 422 communication protocol. With SURB LITE Motor Driver software:
– Course distance definition
– Definition of safe distance
– Definition of test settings enabling successive runs
– Tracking position information
– Monitoring of motor current information
– Tracking speed information in mm/sec
can be monitored by realizing functions such as.
The current limit of ALA-S80-280 is set as 20A
for 100ms. When it encounters a current
above this value, the system switches to protection and
does not work.
ALA-S80-280, according to MIL-STD-810G standard:
Operating Temperature Range, Storage Temperature Range,
Temperature Shock, Solar Radiation, Vibration-Mechanical Shock,
Humidity, Dust, Rain and Sealing, Salt Fog,
Pressure/Altitude, EMI/EMC,
Please ask for detailed information on test methods and procedures.
TECHNICAL DATA
- Operating Voltage: 18 – 33 VDC
- Operating Current: ≤5A @No Load, ≤20A @1000N
- Motor: Brushed DC Motor
- Terminal Resistance: ≥ 0.9 ohm
- Brake: Current: ≤1A Release Voltage VR ≤ 18VDC @20 °C
Position Sensor
Magnetic Encoder
Operating Voltage: 12VDC (5-24VDC)
Output Signal: 2 TTL compatible square waves
Number of signals per round: 2
Low Level Output Voltage: 0.5Vdc (20mA)
Signal Width: > 1ms (at high motor speed,
Input Voltage: 32VDC - Bond Resistance: ≤10 milliohms (Connector to Chassis)
- Connector Type: D38999-20WB35PN
- Axial Load Capacity: 1000 N (nominal) and 1500 N (maximum)
- Course Distance: 280 mm
- Speed: 70 mm/sec linear motion under 24 VDC voltage and 1000 N nominal thrust.
- Color: FED-STD-595B 37030 Black
- Weight: 4.2 kg
- Operating Temperature: -40 °C to +65 °C
- Protection Class: IP68